LR-F series vacuum reflow soldering


Product application scope: The equipment is completely independently developed, combining the strengths of various families and meticulously crafted, targeting vacuum SMT welding of automotive headlights, aerospace, aviation, medical, automotive, BGA, FPC, LED, and other fields.

Classification:

  • DESCRIPTION
    • Commodity name: LR-F series vacuum reflow soldering
    • Commodity ID: LR-F series vacuum reflow solder

    Product application scope: The equipment is completely independently developed, combining the strengths of various families and meticulously crafted, targeting vacuum SMT welding of automotive headlights, aerospace, aviation, medical, automotive, BGA, FPC, LED, and other fields.

    Technical Features & Product Advantages

    1. This equipment is completely independently developed, set up by the strengths of all families, carefully built, vacuum reflow soldering with independent intellectual property rights, and the products are aimed at vacuum SMT welding of automotive headlights, aerospace, aviation, medical, automotive, BGA, FPC, LED, etc.

    2. This equipment adopts industrial control embedded control system, the system adopts dual CPU operation, which can run independently from the computer (computer crash), which is not only stable and reliable, but also has more accurate temperature control.

    3. There are the most models of the same specification, supporting dual-track speed, dual-track single-cavity, double-track dual-cavity, and dual-track multi-purpose.

    4. Double-track and double-cavity, the upper furnace cover of double-track and single-cavity is raised and lowered horizontally, which makes maintenance and maintenance more convenient.

    5. The equipment supports the formula function of key welding parameters and supports MES remote data reading.

    6. Step-by-step vacuum design, up to 5 steps can be vacuumed.

    7. The patented water-cooled structure of the sealing ring not only has a longer life and lower cost, but also reduces the expensive product damage caused by poor sealing.

    8. The maximum vacuum degree can reach 0.1KPa, Void Single <1%, Total <2%.

    9. The fastest cycle time is 30s/percvcle, and the vacuum reflow soldering industry has the highest efficiency.

    10. The warm-up time is about 30min.

     

    Technical Parameters:

    Basic parameters Basic parameters Basic parameters Basic parameters Basic parameters Basic parameters
    Device model LR-F1030L LR-F1030H LR-F1030DS LR-F1030DL LR-F1030DM
    Equipment size (mm) L6300*D1430*H1530 L7100*D1430*H1530 L7100*D1680*H1500 L7100*D1680*H1500 L7100*D1680*H1500
    Machine weight APPROX:3000KG APPROX:3300KG APPROX:3500KG APPROX:3500KG APPROX:3500KG
    Number of heating zones 9 heating zones up and 9 down 10 heating zones up and 10 down 10 heating zones up and 10 down 10 heating zones up and 10 down 10 heating zones up and 10 down
    Number of cooling zones There are 4 cooling zones in total, 2 up, 2 down There are 6 cooling zones in 3 up, 3 down, and 3 in total There are 6 cooling zones in 3 up, 3 down, and 3 in total There are 6 cooling zones in 3 up, 3 down, and 3 in total There are 6 cooling zones in 3 up, 3 down, and 3 in total
    Cooling method Forced water cooling Forced water cooling Forced water cooling Forced water cooling Forced water cooling
    Exhaust requirements 10m³/H*2 10m³/H*2 10m³/H*2 10m³/H*2 10m³/H*2
    Voiding rate APPROX:1%-2% APPROX:1%-2% APPROX:1%-2% APPROX:1%-2% APPROX:1%-2%
    Control system Control system Control system Control system Control system Control system
    Power requirements 3P 380V/220/480 50/60Hz 3P 380V/220/480 50/60Hz 3P 380V/220/480 50/60Hz 3P 380V/220/480 50/60Hz 3P 380V/220/480 50/60Hz
    Total power 68KW 74KW 90KW 85KW 85KW
    Segmented starting power 38KW 40KW 50KW 50KW 50KW
    Power consumption APPROX:10-15KW APPROX:12-18KW APPROX:13-20KW APPROX:13-20KW APPROX:13-20KW
    Hot air blower speed regulation Frequency converters Frequency converters Frequency converters Frequency converters Frequency converters
    Heating time APPROX:30min APPROX:30min APPROX:30min APPROX:30min APPROX:30min
    Temperature control range Room temperature ~300°C can be set Room temperature ~300°C can be set Room temperature ~300°C can be set Room temperature ~300°C can be set Room temperature ~300°C can be set
    Production recipes Multi-combination recipes can be stored Multi-combination recipes can be stored Multi-combination recipes can be stored Multi-combination recipes can be stored Multi-combination recipes can be stored
    Transportation Transportation Transportation Transportation Transportation Transportation
    Track structure Monorail Monorail Dual Dual Dual
    Vacuum structure Single-chamber Single-chamber Double-track and dual-cavity Double-track single-chamber (unilateral vacuum) Double-track single-chamber (bilateral vacuum)
    Vehicle size (mm) L400*D400 L400*D400 L400*D250 L400*D250 L400*D250
    Conveyor belt height(mm) 900±20 900±20 900±20 900±20 900±20
    Shipping method Chain drive Chain drive Chain drive Chain drive Chain drive
    Vacuum system Vacuum system Vacuum system Vacuum system Vacuum system Vacuum system
    Minimum vacuum pressure 0.1KPa 0.1KPa 0.1KPa 0.1KPa 0.1KPa
    Vacuum pump flow 1500L/min 1500L/min 双1000L/min 1000L/min 1500L/min
    Pressure relief time ≤10s ≤10s ≤10s ≤10s ≤10s
    Productivity ≥40S ≥40S ≥40S ≥40S ≥40S
    Optional nitrogen system Optional nitrogen system Optional nitrogen system Optional nitrogen system Optional nitrogen system Optional nitrogen system
    Nitrogen structure Full/local nitrogen filling Full/local nitrogen filling Full/local nitrogen filling Full/local nitrogen filling Full/local nitrogen filling
    Nitrogen system Automatic or manual switchable Automatic or manual switchable Automatic or manual switchable Automatic or manual switchable Automatic or manual switchable
    Nitrogen consumption APPROX:600L/min APPROX:600L/min APPROX:700L/min APPROX:700L/min APPROX:700L/min

    Note: This technical parameter is for reference only, and the actual parameter is set by the technical specifications and production process provided by the manufacturer.